Water Analysis


Coliform Count, MPN / 100ml
(By Multiple Tube Fermentation Technique)
Date of Analysis March 20, 2012

Concessionaire Location Results Specification
Francisco Repato
#861 del Pilar Ext.
1.1
<1.1
METRO BANK
Cagayan Valley Road, Bitas
<1.1
<1.1
Reynaldo Tolentino
347 NEQR, San Isidro
<1.1
<1.1
Lulu R. De Guzman
Ireneville Subd., San Isidro
<1.1
<1.1
Precy T. Rigor
Agri-Chem Supply, CVR Bitas
<1.1
<1.1
E.L. Joson Memorial Hospital
CVR, Daan Sarile
<1.1
<1.1
Don's Auto Surplus Center
CVR Valdefuente
<1.1
<1.1
Joey Pascual
Pagas
<1.1
<1.1
Andrei Nicha
Aduas
<1.1
<1.1
Nicomedes Rivera
Aduas
<1.1
<1.1
Radigunda Antonio
69 Amada St., Kapt. Pepe
<1.1
<1.1
Dominador Mingala Jr.
Sumacab Norte Cab. City
<1.1
<1.1
Sharp Service Center
Cagayan Valley Road
<1.1
<1.1
Arcadio Agulto
044 CVR, ACCFA
<1.1
<1.1
Soroptimist
Magsaysay Norte Cab. City
<1.1
<1.1
Greenside Restaurant
Barrera District
<1.1
<1.1
Coralyn Eatery
Mabini St., (front of PJG Hospital)
<1.1
<1.1
Rowena Ronquillo
Burgos St.
<1.1
<1.1
Felicisimo Rodriguez
Villa Ofelia
<1.1
<1.1
DAMBANA Church
Mabini Ext.
<1.1
<1.1
Alvin Vergara
Caridad Village
<1.1
<1.1
Gerry Cruz
Magsaysay Sur
<1.1
<1.1
Benito Sapugay Sr.
Univille Subd.
<1.1
<1.1
Evelyn Caymo
Putol na Kalye, Mayapyap
<1.1
<1.1
Ailyn Sindac
Imperial
<1.1
<1.1
Lourdes Moratalya
Mayapyap Sur
<1.1
<1.1
Elsa Padilla
Bitas, Cabanatuan City
<1.1
<1.1
Ariel Lumibao
Lexber Homes Subdivision
<1.1
<1.1
Ronald Pangilinan
H. Conception Cabanatuan City
<1.1
<1.1
MERCHANT'S BANK
Cagayan Valley Road
<1.1
<1.1
* Based on the report of INTERTEK Testing Services Philippines, Inc.

REMARKS : MPN/100ml = Most Probable Number per 100 milliliter
CFU/ml = Colony Forming Unit per milliliter
= exceeded the limit
Est = Estimated Count
< = less than
* = Philippine National Standard for Drinking Water, 2007

Water Quality Test - Physical
Date of Analysis Oct 08, 2008

Pump House
Physical Analysis
Metal Analysis
Turbidity (NTU)
Color (Units)
Iron
Manganese
PNSDW
5 TCU
5 TCU
1 mg/L
0.4 mg/L
NEHS
0.24
3
0.04
0.01
Bonifacio
0.40
4
0.042
0.045
Kapt. Pepe
0.57
5
0.042
0.009
Mabini Ext.
Daan Sarile
0.29
2
0.026
0.004
Aduas
0.31
4
0.032
0.004
San Isidro
0.26
2
0.003
0.007
Barrera
0.24
2
0.023
0.004
Melencio
0.24
5
0.040
0.027
Burgos
0.39
3
0.026
0.006
Bitas
0.21
3
0.026
0.004
Don Jose
0.57
5
0.040
0.034
P. Garcia
0.52
5
0.039
0.024
Lourdes
0.35
3
0.037
0.014
Villa Benita
0.32
5
0.040
0.021
Sta. Arcadia
0.44
3
0.036
0.012
Pagas
0.43
3
0.029
0.011
Camp Tinio
0.51
4
0.027
0.003
Grand Victoria
0.47
5
0.052
0.118
Mayapyap (After filtration)
0.25
2
0.022
0.063
Sumacab (After filtration)
0.76
3
0.069
0.071
Imperial
1.98
5
0.043
0.017
* Based on the report of PLATINUM Research Laboratory Inc.

NOTES : MDL = minimum detection limit
nil = not detected
PNSDW = Philippine National Standards for Drinking Water

Water Quality Test - Chemical
Date of Analysis Oct 08, 2008

Pump House
Chemical Analysis
pH
Total dissolved solids(mg/L)
Sulfate
Nitrate
Chloride
PNSDW
6.5-8.5
500
250
50
250
NEHS
7.42
226
30
Bonifacio
7.77
237
10
Kapt. Pepe
7.86
291
57
Mabini Ext.
Daan Sarile
7.94
189
15
Aduas
7.01
216
22
San Isidro
7.34
221
10
Barrera
7.53
227
15
Melencio
7.22
217
12
Burgos
7.78
200
7
Bitas
8.25
190
20
Don Jose
7.20
228
7
P. Garcia
7.25
224
7
Lourdes
6.90
262
25
Villa Benita
7.87
253
7
Sta. Arcadia
7.30
255
7
Pagas
6.54
202
15
Camp Tinio
9.22
275
52
Grand Victoria
7.10
308
10
Mayapyap (After filtration)
7.66
259
10
Sumacab (After filtration)
7.73
255
10
Imperial
7.41
283
10
* Based on the report of PLATINUM Research Laboratory Inc.

NOTES : MDL = minimum detection limit
nil = not detected
PNSDW = Philippine National Standards for Drinking Water